The Spine Journal
Volume 10, Issue 3 , Pages 244-251 , March 2010

Determination of the in vivo posterior loading environment of the Coflex interlaminar-interspinous implant

  • Frank T. Trautwein, Dipl-Ing(FH)

      Affiliations

    • Paradigm Spine, GmbH, Eisenbahnstrasse 84, D-78573 Wurmlingen, Germany
    • Corresponding Author InformationCorresponding author. Paradigm Spine, GmbH, Eisenbahnstrasse 84, D-78567 Wurmlingen, Germany. Tel.: (49) 711-7874-162; fax: (49) 711-7874-163.
  • ,
  • Gary L. Lowery, MD, PhD

      Affiliations

    • Paradigm Spine, LLC, 505 Park Ave., 14th Floor, New York, NY 10022, USA
  • ,
  • Nicholas D. Wharton, MS

      Affiliations

    • Medical Metrics, Inc., Houston, TX 77027, USA
  • ,
  • John A. Hipp, PhD

      Affiliations

    • Medical Metrics, Inc., Houston, TX 77027, USA
  • ,
  • Robert J. Chomiak, MS

      Affiliations

    • Paradigm Spine, GmbH, Eisenbahnstrasse 84, D-78573 Wurmlingen, Germany

Received 10 March 2009 ,Revised 15 September 2009 ,Accepted 20 October 2009.

References 

  1. Arnoldi CC, Brodsky AE, Cauchoix J, et al. Lumbar spinal stenosis and nerve root entrapment syndrome. Definition and classification. Clin Orthop. 1976;115:4–5
  2. Yong-Hing K, Kirkaldy-Willis WH. The pathophysiology of degenerative disease of the lumbar spine. Orthop Clin North Am. 1983;14:501–503
  3. Delamarter RB, Howard M. Lumbar spinal stenosis. Rehabilitation of the spine, science and practice. In:  Hochschuler S,  Cotler H,  Guyer R editor. Chicago: Mosby; 1993;p. 443–456
  4. Deyo RA, Rainville J, Kent DL. What can the history of physical examination tell us about low back pain?. JAMA. 1992;268:760–765
  5. Treatment of degenerative lumbar spinal stenosis. Summary, evidence report/technology assessment: number 32. AHRQ Publication No. 01–E047 Rockville, MD: Agency for Healthcare Research and Quality; 2001;Available at:http://www.ahrq.gov/clinic/epcsums/stenosum.htm. Accessed February 15, 2006
  6. Wiseman CM, Lindsey DP, Fredrick AD, Yerby SA. The effect of an interspinous process implant on facet loading during extension. Spine. 2005;30:903–907
  7. Prasad P, King AI. An experimentally validated dynamic model of the spine. J Appl Mech. 1974;41:546–550
  8. Yerby SA, Lindsey DP, Kreshak J. Failure load of the lumbar spinous process. Transactions of the 47th Annual Meeting of the Orthopaedic Research Society; February 25–28, 2001; San Francisco, CA.
  9. Shepherd DET, Leahy JC, Mathias KJ, et al. Spinous process strength. Spine. 2000;25:319–323
  10. Wenger D, Miller S, Wilkerson J. Evaluation of fixation sites for segmental instrumentation of the human vertebrae. Orthop Trans. 1982;6:23–24
  11. Ochia R, Ching R. Internal pressure measurements during burst fracture formation in human lumbar vertebrae. Spine. 2002;27:1160–1167
  12. White A, Panjabi M. Clinical biomechanics of the spine. 2nd ed. Philadelphia: Lippincott Williams and Wilkins; 1990;
  13. Benzel E. Biomechanics of spine stabilization: principles and clinical practice. New York, NY: McGraw-Hill, Health Professions Division; 1995;4
  14. Ettinger C, Kaddick C. Static axial compression test report no. 107.041117.30.261. Rosenheim, Germany: Endolab Mechanical Engineering, GmbH, July 5, 2005.
  15. Trautwein FT. Finite element analysis report no. 2005.0021. Load deflection analysis on coflex™ implants. ACES Ing.-GmbH, Filderstadt, Germany, December 19, 2005.
  16. Zhao K, Yang C, Zhao C, An K-N. Assessment of non-invasive intervertebral motion measurements in the lumbar spine. J Biomech. 2005;38:1943–1946
  17. Trautwein FT. Coflex™ load bearing capability. Paradigm Spine, GmbH Internal Memorandum, March 8, 2006.
  18. Bernhart M, Ettinger C. Static axial compression bending test report no. 107.060227.30.372. Rosenheim, Germany: Endolab Mechanical Engineering, GmbH, March 1, 2006.
  19. Wilke HJ, Heuer F, Häussler K, et al. Strain gauge measurements on the interspinous “U“ coflex™, report no. 493-01, Ulm, Germany. Strain Gauges, September 2005.
  20. Ettinger C, Kaddick C. Lateral wing bending fatigue test report no. 107.041117.30.261. Rosenheim, Germany: Endolab Mechanical Engineering, GmbH, March 1, 2005.
  21. Ettinger C, Bernhart M. Dynamic compression bending test report no. 107.051123.30.353. Rosenheim, Germany: Endolab Mechanical Engineering, GmbH, March 7, 2006.
  22. Zioupos P, Gresle M, Winwood K. Fatigue strength of human cortical bone: age, physical, and material heterogeneity effects. J Biomed Mater Res A. 2008;86:627–636

 FDA device/drug status: not applicable.

 Author disclosures: FTT (stock ownership, private investments, Paradigm Spine, LLC; others, ACES GmbH); GLL (stock ownership, private investments, trips/travel, other office, Paradigm Spine, LLC); JAH (stock ownership, Medical Metrics, Inc; other office, Medical Metrics, Inc; grants, DARPA); RJC (stock ownership, private investments, Paradigm Spine, LLC; others, MCRA, LLC).

PII: S1529-9430(09)01052-3

doi: 10.1016/j.spinee.2009.10.010

The Spine Journal
Volume 10, Issue 3 , Pages 244-251 , March 2010